2.1Controllable circuit
X20 is a standalone climate controller. It supports:
- 8NTC Temperature sensors(6 indoor, 1 outdoor or water temperature) input
- 1 Humidity sensor input
- 1 NH3 sensor input
- 1 CO2 sensor input
- 1 Static pressure sensor input
- 2 Digital input ( pulse water meter and feeding pulse)
- 2 Variable frequency fan
- 18 groups of Constant speed fan
- 3 Mixing fan
- 3 cooling control
11)4 heaters control
12)1 lighting control
13)1 alarm output
14)2 inlet motor and 3 curtain motor

2.2Controller chassis
It adopts a fully enclosed chassis, made of all environmentally friendly materials, and sealed with silicone rubber, which can ensure long-term dustproof, waterproof, and high-temperature resistance
2.3Touch screen display. The waterproof level and protection level are IP67 and IK08, respectively.
The display module adopts DMG series resistor screen (7 inch 800×480 resolution), can store up to 32MB of font and 256MB of images, providing a clearer and more effective interface for display, detection, and parameter settings.
2.4Control Object
The controller mainly controls systems such as fans, heating devices, Ventilation Systems, humidification systems, cooling systems, and lighting intensity.
The controller can also detect the amount of water and food, accurately controlling the living environment of livestock and poultry.
The controller can provide output and input signals of 0-10V and 4-20mA, achieving various signal detection.
2.5 Install
1) Fix the four fixing brackets inside the environmental controller to the four corners on the back of the controller with screws. φ5 mounting holes, using φ5 self tapping screws are installed on a dry wall 1 meter away from the electric control box.
2) Connect the sensor to the sensor input terminal of the environmental controller.
3) Equipped with an external drive module, the analog output (0-10V) can control the Variable frequency fan and control the lighting.
4) Connect the relay output to the corresponding device, and the relay outputs are all dry contacts 5A/220V NO/NC.
5) Connect the 220V, 50Hz/60Hz power supply to the environmental controller through a cable and ensure proper grounding.